Your position:Home > Products > Weighing Indicator >

T380 weighing Indicator

Posted: Views:
Features

◆Adopt the technology of three-integral, 16 kinds of capacity can be chose.  
◆Calibration without full-capacity, data inputting with only one key.  
◆Many types of filter parameter setting.  
◆Many types of division can be selected.  
◆The position of point can be selected.  
◆ Zero-tracking range and zero-catching can be selected.  
◆Many types of print-mode can be selected.  
◆Two fixed-value can be set. It can be used in value setting and alarm.  
◆Many types of baud rate and transmit format selection,successive transmission and net-communication with 26 (52) pieces can be selected.  
◆Date, time, vehicle number, cargo number, unit-price, fixed value 1, fixed value 2 setting.  
◆Weight, sum, total times, total weight, total sum display and printing.  
◆Positive and negative peak value test  .  
◆Data protection when power off.

Main Technical Data
Accuracy class   OIML Ⅲ  
Display   7 digits 0.5 inch LED display  
Keyboard   5 function keys  
Division   1; 2; 5; 10; 20; 50  
Tare range   100% F.S.
Max.Number of load cells   4×350Ω  
Supply voltage   V   AC: ~220V (-15%…+10%)
Hz   50  
/DC: 6V  
Max.power consumption   VA 6  
Fusible-ling fuse(sloe blow)   A   1
Communicate interface     RS-232
Print interface     Parallel interface,contact with micro-printer
Storange –humidity     ≤70% RH
working –humidity     ≤90% RH
Storange –temperature   ℃   -10…+50 RH
working–temperature   ℃   0…+40 RH
Outline   mm   170×70×105
Weight   kg   0.6


T380 Keyboard Rigure

LOAD CELLS TO INDICATOR Note: 
● +E、-E:Load cell's power.  
● +S、-S:Load cell's feedback signal.  
● +IN、-IN:Load cell's output signal.  
● It is 9-pin plug.  
● If using the shielded 4-pin cable, you must connect  
+E,+S and -E,-S.Otherwise it will affect the indicator.  
● After connecting the load cell, the indicator should  
be turned on. Otherwise the display will be abnormal.